Description: Accuenergy ACUVIM-CL-D-5A-P1V4 Power/Energy Meter, LCD, RS485, 5 A input, 415 Vac/300 Vdc Model: ACUVIM-CL-D-5A-P1V4 | Order No:ACUVIM-CL-D-5A-P1V4 Multifunction power meter with integrated LCD display, Modbus RTU output, 5 A input for current transformers and wide-range AC power supply input. Brand: Model: ACUVIM-CL-D-5A-P1V4 Order No: ACUVIM-CL-D-5A-P1V4 Condition: NEW Description Accuenergy ACUVIM-CL-D-5A-P1V4 Power/Energy Meter, LCD, RS485, 5 A input, 415 Vac/300 Vdc Accuenergy Acuvim CL-D-5A-P1 Offers Panel metering is key to understanding energy consumption in homes, buildings, and facilities. The Accuenergy Acuvim CL includes a digital RS485 communication port running Modbus protocol. This model also includes 5A current input, 100 to 415V AC, 50/60Hz, 100 to 300V DC power supply, and integrated LCD display.FeaturesTrue-RMS measurement parameters so that non-linear loads can be monitored4-quadrant energy measurementPower quality analysisOver/Under limit alarmMax/Min statisticsMeter running time Included Accuenergy ACUVIM-CL-D-5A-P1V4 Power/Energy Meter, LCD, RS485, 5 A input, 415 Vac/300 Vdc Specifications SpecificationsMeteringParametersAcuvim-L AccuracyAcuvim-EL/KL AccuracyResolutionRangeVoltage0.5%0.5%0.1V20V~1000kVCurrent0.5%0.5%0.001A0~50000ACurrent Demand0.5%0.5%0.001A0~50000APower1.0%0.5%1W-9999MW~9999MWReactive Power2.0%0.5%1var-9999Mvar~9999MvarApparent Power1.0%0.5%0.001V0~9999MVAPower Demand1.0%0.5%1W-9999MW~9999MWReactive Power Demand2.0%0.5%1var-9999Mvar~9999MvarApparent Power Demand1.0%1VA1VA0~9999MVAPower Factor1.0%0.5%0.001-1.0~1.0Frequency0.2%0.2%0.01Hz45.00~65.00HzEnergy0.5%0.5%0.1kWh0~99999999.9kWhReactive Energy2.0%0.5%0.1kvarh0~99999999.9kvarhApparent Energy1.0%0.5%0.1VAh0~99999999.9kVAhHarmonics2.0%-0.01%0~100.0%Running Time0.1hrs0~999999999.9hrsCommunicationRS-485 (Option)Modbus-RTU Protocol2-wire connection, Half-duplex, Isolated1200 to 38400 baud rateInputCurrent Inputs (Each Channel)Nominal Current5 A acMetering Range0~6 A acWithstand20Arms continuous100Arms for 1 second, non-recurringBurden0.05VA (typical) @5ArmsPickup Current10VacAccuracy0.5%Voltage Inputs (Each Channel)Nominal Full Scale400Vac L-N, 690Vac L-L (+20%)Withstand1500Vac continuous2500Vac, 50/60Hz for 1minuteInput Impedance45Hz~65HzPickup Voltage10VacAccuracy0.5%Energy Accuracy (Acuvim-EL)Active(according to IEC 62053-22) Class 0.5s(according to ANSI C12.20) Class 0.5Reactive(according to IEC 62053-23) Class 2Harmonic ResolutionMetered Value2nd ~ 15th harmonics(THD of Acuvim-DL is 2nd to 25th)Control PowerUniversalAC or DCAC/DC Control PowerOperating Range100~415Vac, 50/60Hz, 100~300VdcBurden3WWithstand3250Vac, 50/60Hz for 1 minuteLow Voltage DC Control Power (Optional)Operating Range20~60VdxBurden3WDigital Output OptionDigital Output (DO)(Photo-MOS)Voltage Range0~250Vac/dcLoad Current100mA (Max)Output Frequency25Hz, 50% Duty RatioIsolation Voltage2500VDigital Input OptionDigital Output (DI)Input Voltage Range20~250Vac/dcInput Current (Max)2mAStart Voltage15VStop Voltage5VPulse Frequency (Max)100Hz, 50% Duty RatioSOE Resolution2msOperating EnvironmentOperation Temperature-25°C to 70°CStorage Temperature-40°C to 85°CRelative Humidity5% to 95% non-condensingPollution Degree2Standard ComplianceProductUSAUL 61010-1CanadacUL 61010-1EuropeIEC 61010-1EmissionRadiated/ConductedFCC Part 15 Subpart B, Class ARadiated/ConductedEN 55011HarmonicIEC 61000-3-2Voltage FluctuationIEC 50081-2Radio InterferenceIEC 50081-2ImmunityESDIEC 61000-4-2Radiated, radio-frequency, electromagnetic fieldIEC 61000-4-3Electrical fast transient/bustIEC 61000-4-4SurgeIEC 61000-4-5Conducted disturbancesIEC 61000-4-6Power frequency magnetic fieldIEC 61000-4-8Voltage dips and interruptionsIEC 61000-4-11Generic Immunity Standard for Industrial EnvironmentEN 50082-2 Terms & Conditions Item Condition: Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty. Shipping: We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank. Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection. *Shipping Rates are for Continental US, Please Contact us for other US Destinations Payment: Currently all payments must be made directly though PayPal Sales Tax: We are required to charge sales tax in North Carolina Return Policy: If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition. Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.
Price: 363.4 USD
Location: Wilmington, North Carolina
End Time: 2024-11-19T02:02:41.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Return policy details:
Brand: Accuenergy
MPN: ACUVIM-CL-D-5A-P1V4